Soft-Start Circuit Design Using Relays  

โดย : Gladis   เมื่อวันที่ : พุธ ที่ 8 เดือน ตุลาคม พ.ศ.2568   


</p><br><p>Applying relay-based soft-start techniques is a practical way to limit startup current and enhance durability of power loads. When devices like motors are powered on suddenly, they can draw a large surge of current that causes voltage dips in the distribution system. A gradual power ramp-up ramps voltage, preventing supply instability. While solid-state solutions like SCRs are common for soft-start, electromechanical switches can still be used reliably with the smart circuit architecture.<br></p><img src="https://learnosm.org/images/josm/JOSM_TMS_3.png" alt="LearnOSM" style="max-width:430px;float:left;padding:10px 10px 10px 0px;border:0px;"><br><p>To begin you need a primary contactor that delivers full voltage to the device and a timing circuit that manages the timing. The timing unit typically includes a programmable timer or a PLC that implements a postponement before the primary contact closes. In some cases, a resistor or an choke is placed in between source and load during the initial phase to reduce peak demand. This component is then removed from circuit after a preset interval using a multi-pole relay or by the auxiliary contacts on the main unit.<br></p><br><p>As an illustration: <a href="https://doc.aquilenet.fr/tIzx6lCKQw-FB4HKBTS_Aw/">_____ ___</a> you can wire a resistor in parallel with a normally open auxiliary contact on the main relay. When power is applied, the inrush path goes through the limiter, reducing peak current. After a adjustable interval between 1_10 sec, the delay expires and the bypass contact closes, bypassing the limiter and allowing full current to flow. This creates a smooth transition from partial to full load.<br></p><br><p>You must select parts rated for the system ratings. The current limiter must handle the initial power dissipation without overheating, so select a robust power resistor with proper thermal management. The relay contacts must also be rated for motor starting and startup surge. Electromechanical contactors have wear-out limitations, so avoid rapid cycling and set sufficient hold time to prolong contact life.<br></p><br><p>For added safety, consider using a thermal overload protector in connected to the output. Even with soft-start, unexpected surges or prolonged operation can lead to overheating. Monitoring the temperature of the bypass element or installing a CT to initiate the transition can enable adaptive control, making it more adaptive to varying load conditions.<br></p><br><p>Electromechanical soft-start is not as accurate or low-loss as electronic solutions, but it is affordable, robust, and simple to diagnose. It is suited for harsh environments where long-term reliability matter more than fine control. With careful part matching and timing, this approach can dramatically extend equipment life and reduce maintenance costs. Always test the circuit under load conditions and ensure no arcing or spikes and that the inrush current is within acceptable limits.<br></p>

เข้าชม : 3



กำลังแสดงหน้าที่ 1/0 ->
<< 1 >>





Re หัวข้อ :
รูปประกอบ : Limit 100 kB
ไอคอน : ย่อหน้า จัดซ้าย จัดกลาง จัดขวา ตัวหนา ตัวเอียง เส้นใต้ ตัวยก ตัวห้อย ตัวหนังสือเรืองแสง ตัวหนังสือมีเงา สีแดง สีเขียว สีน้ำเงิน สีส้ม สีชมพู สีเทา
อ้างอิงคำพูด เพิ่มเพลง เพิ่มวีดีโอคลิป เพิ่มรูปภาพ เพิ่มไฟล์ Flash เพิ่มลิงก์ เพิ่มอีเมล์
รายละเอียด :
ใส่รหัสที่ท่านเห็นลงในช่องนี้
ชื่อของท่าน :


  
สำนักงานเทศบาลตำบลนครชุม
๙๙๙ ถนนพหลโยธิน ต.นครชุม จังหวัด กำแพงเพชร ๖๒๐๐๐ โทรศัพท์ ๐๕๕-๗๓๘๘๖๘-๙
Based on : Maxsite1.10 Modified to AtomyMaxsite 1.50